Abstract

ObjectivesThe most important goal of surgical treatment for spinal degeneration, in addition to eliminating the underlying pathology, is to preserve the biomechanically relevant structures. If degeneration destroys biomechanics, the single segment must either be surgically stabilized or functionally replaced by prosthetic restoration. This study examines how software-based presurgical simulation affects device selection and device development.MethodsBased on videofluoroscopic motion recordings and pixel-precise processing of the segmental motion patterns, a software-based surrogate functional model was validated. It characterizes the individual movement of spinal segments relative to corresponding cervical or lumbar spine sections. The single segment-based motion of cervical or lumbar spine of individual patients can be simulated, if size-calibrated functional X-rays of the relevant spine section are available. The software plug-in “biokinemetric triangle” has been then integrated into this software to perform comparative segmental motion analyses before and after treatment in two cervical device studies: the correlation of implant-induced changes in the movement geometry and patient-related outcome was examined to investigate, whether this surrogate model could provide a guideline for implant selection and future implant development.ResultsFor its validation in 253 randomly selected patients requiring single-level cervical (n=122) or lumbar (n=131) implant-supported restoration, the biokinemetric triangle provided significant pattern recognition in comparable investigations (p<0.05) and the software detected device-specific changes after implant-treatment (p<0.01). Subsequently, 104 patients, who underwent cervical discectomy, showed a correlation of the neck disability index with implant-specific changes in their segmental movement geometry: the preoperative simulation supported the best choice of surgical implants, since the best outcome resulted from restricting the extent of the movement of adjacent segments influenced by the technical mechanism of the respective device (p<0.05).ConclusionsThe implant restoration resulted in best outcome which modified intersegmental communication in a way that the segments adjacent to the implanted segment undergo less change in their own movement geometry. Based on our software-surrogate, individualized devices could be created that slow down further degeneration of adjacent segments by influencing the intersegmental communication of the motion segments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.