Abstract
Fifty-one patients available for a 2 1/2 year follow-up after intracapsular cataract extraction and implantation of the semiflexible McGhan/3M, style 70 anterior chamber lens were evaluated for intraocular pressure (IOP). No significant change in the IOP could be demonstrated despite progression of iris-like tissue adhesions between the iris and lens haptics at or close to the trabecular meshwork. Four eyes (7.8%) had IOPs ≥ 22 mm Hg without medication, and four other eyes used timolol eyedrops with subsequent IOPs ≤ 18 mm Hg. Eight eyes (15.7%) demonstrated an IOP increase ≥ 25% over baseline pressures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.