BackgroundInappropriately cuffed tracheal tubes can lead to inadequate ventilation or silent aspiration, or to serious tracheal damage. Cuff pressures are of particular importance during aeromedical transport as they increase due to decreased atmospheric pressure at flight level. We hypothesised, that cuff pressures are frequently too high in emergency and critically ill patients but are dependent on providers’ professional background.MethodsTracheal cuff pressures in patients intubated before arrival of a helicopter-based rescue team were prospectively recorded during a 12-month period. Information about the method used for initial cuff pressure assessment, profession of provider and time since intubation was collected by interview during patient handover. Indications for helicopter missions were either Intensive Care Unit (ICU) transports or emergency transfers. ICU transports were between ICUs of two hospitals. Emergency transfers were either evacuation from the scene or transfer from an emergency department to a higher facility.ResultsThis study included 101 patients scheduled for aeromedical transport. Median cuff pressure measured at handover was 45 (25.0/80.0) cmH2O; range, 8-120 cmH2O. There was no difference between patient characteristics and tracheal tube-size or whether anaesthesia personnel or non-anaesthesia personnel inflated the cuff (30 (24.8/70.0) cmH2O vs. 50 (28.0/90.0) cmH2O); p = 0.113.With regard to mission type (63 patients underwent an emergency transfer, 38 patients an ICU transport), median cuff pressure was different: 58 (30.0/100.0) cmH2O in emergency transfers vs. 30 (20.0/45.8) cmH2O in inter-ICU transports; p < 0.001. For cuff pressure assessment by the intubating team, a manometer had been applied in 2 of 59 emergency transfers and in 20 of 34 inter-ICU transports (method was unknown for 4 cases each). If a manometer was used, median cuff pressure was 27 (20.0/30.0) cmH2O, if not 70 (47.3/102.8) cmH2O; p < 0.001.ConclusionsCuff pressures in the pre-hospital setting and in intensive care units are often too high. Interestingly, there is no significant difference between non-anaesthesia and anaesthesia personnel. Acceptable cuff pressures are best achieved when a cuff pressure manometer has been used. This method seems to be the only feasible one and is recommended for general use.

Highlights

  • Cuffed tracheal tubes can lead to inadequate ventilation or silent aspiration, or to serious tracheal damage

  • For emergency patients, tracheal intubation with a cuffed tube remains the gold standard for securing the airway

  • There was no difference in cuff pressures dependent on patient characteristics or tracheal tube diameter

Read more

Summary

Introduction

Cuffed tracheal tubes can lead to inadequate ventilation or silent aspiration, or to serious tracheal damage. That cuff pressures are frequently too high in emergency and critically ill patients but are dependent on providers’ professional background. Tracheal intubation with a cuffed tube remains the gold standard for securing the airway. Compared with other airway tools, only cuffed tracheal tubes are able to prevent aspiration. For controlled ventilation, air leakage must be minimised. This is especially important during the transfer and relocation of patients. There is evidence from studies and case reports that over-inflation of the tracheal cuff can cause various complications including rather benign complaints such as sore throat or hoarseness and mild mucosal damage expressed by transient blood-streaked expectorant [4,5,6], and serious complications such as tracheal stenosis or even tracheoesophageal fistula or tracheal rupture [7,8,9,10,11,12]

Methods
Results
Discussion
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.