Abstract

BACKGROUND CONTEXTVarious total disc replacement (TDR) designs have been compared to anterior cervical discectomy and fusion (ACDF) with favorable short and long-term outcomes in FDA-approved investigational device exemption (IDE) trials. The unique design of M6-C, with a compressible viscoelastic nuclear core and an annular structure, has previously demonstrated favorable clinical outcomes through 24 months. PURPOSETo evaluate the long-term safety and effectiveness of the M6-C compressible artificial cervical disc and compare to ACDF at 5 years. STUDY DESIGNProspective, multicenter, concurrently and historically controlled, FDA-approved IDE clinical trial. PATIENT SAMPLESubjects with one-level symptomatic degenerative cervical radiculopathy were enrolled and received M6-C (n=160) or ACDF (n=189) treatment as part of the IDE study. Safety outcomes were evaluated at 5 years for all subjects. The primary effectiveness endpoint was available at 5 years for 113 M6-C subjects and 106 ACDF controls. OUTCOME MEASURESThe primary endpoint of this analysis was composite clinical success (CCS) at 60 months. Secondary endpoints were function and pain (neck disability index, VAS), physical quality of life (SF-36, SF-12), safety, neurologic, and radiographic assessments. METHODSPropensity score subclassification was used to control for selection bias and match baseline covariates of the control group to the M6-C subjects. Sixty-month CCS rates were estimated for each treatment group using a generalized linear model controlling for propensity score. RESULTSAt 5 years postoperatively, the M6-C treatment resulted in 82.3% CCS while the ACDF group showed 67.0% CCS (superiority p=.013). Secondary endpoints indicated that significantly more M6-C subjects achieved VAS neck and arm pain improvements and showed maintained or improved physical functioning on quality-of-life measures compared to baseline assessments. The M6-C group-maintained flexion-extension motion, with significantly greater increases from baseline disc height and disc angle than observed in the control group. The rates of M6-C subsequent surgical interventions (SSI; 3.1%) and definitely device- or procedure-related serious adverse events (SAE failure; 3.1%) were similar to ACDF rates (SSI=5.3%, SAE failure=4.8%; p>.05 for both). CONCLUSIONSSubjects treated with the M6-C artificial disc demonstrated superior 5-year achievement of clinical success when compared to ACDF controls. In addition, significantly more subjects in the M6-C group showed improved pain and physical functioning scores than observed in ACDF subjects, with no difference in reoperation rates or safety outcomes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.