Abstract
To prospectively compare diagnostic performance of conventional Doppler ultrasonography (US) and microbubble contrast material-enhanced US for assessment of vascular complications after liver transplantation, with clinical follow-up or angiography as reference standard. This study was approved by institutional review board and was HIPAA compliant. Written informed consent was obtained. Seventy-two patients (49 men, 23 women; average age, 52.3 years) were included in this study. Patients who had undergone liver transplantation underwent conventional color Doppler and contrast-enhanced US of the liver. Quality of hepatic artery (HA) and portal vein (PV) visualization, contrast material arrival time, and time for complete evaluation of vasculature were compared for both techniques. McNemar test was used to compare vascular flow visualization scores; Student t test was used to compare mean study times with both techniques. Patients without HA flow at Doppler US underwent angiography; those with flow were followed up clinically. McNemar test was used to compare sensitivity of both techniques. Contrast-enhanced US helped significantly improve flow visualization in hepatic vessels (P < .001). Mean contrast material arrival time was 13.7 seconds +/- 3.8 (standard deviation) in proper HA and 20.7 seconds +/- 6.3 in PV. Mean study time decreased from 27.4 minutes +/- 13.9 to 9.3 minutes +/- 4.5 (P < .01). Doppler US failed to depict HA flow in eight patients; contrast-enhanced US showed flow in six and no flow in two of these patients. Follow-up results confirmed contrast-enhanced US findings. Sensitivity, specificity, and accuracy for Doppler US were 91.3%, 100%, and 91.5%, respectively. Sensitivity, specificity, and accuracy of contrast-enhanced US were all 100%. Sensitivity and accuracy values of the two techniques were significantly different (P < .014); there was no significant difference in specificity (P > .99) Contrast-enhanced US helped improve flow visualization in the HA and PV, decrease scanning time, and correctly differentiate between thrombosis and a patent artery in patients without HA flow at conventional Doppler US.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.