Abstract

The objective of this study was to analyzed the impact of needle gauge (G) on the adequacy of specimens and hemorrhagic complications in pediatric patients undergoing ultrasound (US)-guided transplanted liver biopsies. The study included 300 consecutive biopsies performed in 282 pediatric patients (mean age 6.75 ± 3.82years, range 0.84-17.90) between December 2020 and April 2022. All pediatric patients that referred to our institution for US-guided core-needle liver biopsy (CNLB) were randomized to undergo 16-G or 18-G CNLB. Hemorrhagic complications were qualitatively evaluated. The number of complete portal tracts (CPTs) per specimen was counted and specimen adequacy was assessed based on the American Association for the Study of Liver Diseases guidelines. The incidence of bleeding was 7.00% (n = 21) and adequate specimens for accurate pathological diagnosis were obtained from 98.33% (n = 295) of patients. There was no significant difference in the incidence or amount of bleeding between the 16-G and 18-G groups (11 vs 10, p = 0.821; 35.0mL vs 31.3mL, p = 0.705). Although biopsies obtained using a 16-G needle contained more complete portal tracts than those obtained using an 18-G needle (20.0 vs 18.0, p = 0.029), there was no significant difference in specimen inadequacy according to needle gauge (2 vs 3, p = 1.000). Biopsy with a 16-G needle was associated with a greater number of CPTs but did not increase the adequate specimen rate. There was no significant difference in the complication rate between 16-G biopsy and 18-G biopsy.