Abstract

This paper presents wind-induced response reduction in a very slender building using smart dampers with proposed bracings-lever mechanism system. The building presents a case study of an engineered design that is instructive. The paper shows that shear response and flexural response of tall buildings present two very different cases for vibration suppression. Smart dampers are implemented optimally in the building to reduce its response in the lateral directions for both structural safety and occupant comfort concerns. New bracings-lever mechanism configurations are proposed for the dampers to improve their performance. The study shows how the proposed configurations can enable application to flexural response and scenarios where the interstory drift is not enough for dampers to work effectively. In addition, a decentralized bang-bang controller improved the performance of the smart dampers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.