Abstract

Introduction The aim of this study was to propose a method of electrodes positioning on the superficial masseter and anterior temporalis muscles for surface electromyographic (sEMG) recordings in order to overcome some known methodological constraints. Methods Fifteen volunteers with normal occlusion participated in two experimental sessions within a 7 day-period. Surface electrodes were placed on two different locations that were based on palpable and individual anatomical references. Surface EMG signals (2000 Hz per channel; A/D: 16 bits; gain: 2000 X; band-pass filter: 20-500 Hz) were recorded under three conditions: mandibular rest position, 30% and 100% of maximum voluntary bite force. Three measurements of maximal bite force were taken by using a force transducer positioned over the lower right first molar region and the highest record was taken into account. The root mean square value was considered for analysis. Intraclass correlation coefficients (ICCs), paired t test, and the Bland-Altman method comprised the statistical analyses. The level of significance was set at 0.05. Results ICC records for right and left masseter and anterior temporalis muscles at T0 (first sEMG record) and T7 (second sEMG record) intervals were significantly different (p<0.05). The results showed satisfactory to excellent reproducibility of RMS values at rest, MVBF and 30% MVBF, as well as for MVBF in kgf. Conclusion The results showed reliable reproducibility for the sEMG signal recording in masseter and anterior temporalis muscles from the protocols presented and under the three conditions investigated.

Highlights

  • The aim of this study was to propose a method of electrodes positioning on the superficial masseter and anterior temporalis muscles for surface electromyographic recordings in order to overcome some known methodological constraints

  • The surface electromyographic (sEMG) signals were recorded from superficial masseter (SM) and anterior temporalis (AT) muscles at mandibular rest position, maximum voluntary bite force (MVBF - kgf) and 30% of MVBF

  • The sEMG signal is variable by nature, even within few seconds between recordings (Donaldson and Donaldson, 1990; Hermens et al, 2000; Merletti and Parker, 2004)

Read more

Summary

Introduction

The aim of this study was to propose a method of electrodes positioning on the superficial masseter and anterior temporalis muscles for surface electromyographic (sEMG) recordings in order to overcome some known methodological constraints. Surface EMG signals (2000 Hz per channel; A/D: 16 bits; gain: 2000 X; band‐pass filter: 20-500 Hz) were recorded under three conditions: mandibular rest position, 30% and 100% of maximum voluntary bite force. Results: ICC records for right and left masseter and anterior temporalis muscles at T0 (first sEMG record) and T7 (second sEMG record) intervals were significantly different (p

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call