Abstract

The realization of RF primary power standards by means of microcalorimeter technique requires huge measurement times because the necessity of performing in completely separated steps the standard measurement and the system calibration. This procedure is very detrimental for the final measurement accuracy, therefore, in the paper, a new design is proposed of broadband microcalorimeter, which with an improved hardware and convenient new algorithms allows a self-calibration of the system without dismounting/mounting operation. A four times shorter measurement time, without accuracy loss, together with the improvements of the thermal noise rejection and in the measured data correlation, are the most significant results obtainable.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.