Abstract
The performance of a wood wall connected by wood nails and twist nails was tested. It was found that during the monotonic load testing, the wood nails connected to the shear panel and stud at the column bottom broke when the deformation reached 12.1 mm. However, the primary failure mode was that the twist nails bent and the head cap became dented in the shear panel. For reciprocating loads, it was found that the wood nails experienced local fracture on the tensile side. The skeleton curve of the wood wall connected by twist nails showed a good trend of bearing capacity changes in both tension and compression sides. Based on the properties of the standard wood wall, a new T-shaped fastener was designed for the midply wood wall. The lateral performance of the reinforced standard wood shear wall and midply wood shear wall were tested. By adding T-shaped pull-up fasteners, sandwich wall structure and double row nails, the strength, stiffness, and ductility of the midply wood wall were substantially better than those of standard walls connected with twist nails using conventional pull-up fasteners.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.