Abstract

The article discusses possibilities for use fine ground glass obtained from fluorescent lamp utilisation as micro filler in High Performance Concrete (HPC). Investigated mix compositions are based on silica fume (SF) and SF combination with glass powder. Testing results indicates that replacing silica fume by additionally ground fluorescent glass (up to 50%) slightly increasing consumption of water and delaying setting time of cement paste. All HPC mixes with glass powder showing decreased early-age strength and considerable strength gain after long-term hardening. It is concluded, that the best way of glass application in HPC is use fine ground glass powder together with silica fume as complex admixture.