Abstract
This paper presents an experimental investigation on the performance of self-compacting concrete (SCC) subjected to high temperatures. For this purpose, Portland cement was replaced with fly ash (FA) and granulated blast furnace slag (GBFS) in various proportions with and without polypropylene (PP) fibers and the PP fiber content was 2 kg/m 3 for the mixtures that contained fibers. When the specimens were 56 days old, they were heated to elevated temperatures (200, 400, 600 or 800 °C). Afterword, tests were conducted to determine the weight loss and the compressive strength. Moreover, the change in the ultrasonic pulse velocity (UPV) was determined, and observations for surface cracks were made after the specimens were exposed to elevated temperatures. A severe strength loss was observed for all of the concretes after 600 °C, particularly for the concretes that contained PP fibers; however, the fibers reduced and eliminated the risk of explosive spalling. Based on the test results, it can be concluded that the performance of FA concrete is better than that of the GBFS concrete.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.