Abstract

ObjectiveAdverse outcomes observed late in the Nellix EndoVascular Aneurysm Sealing (EVAS) System (Endologix, Inc, Irvine, Calif) investigational device exemption trial prompted refinement of the anatomic instructions for use (IFU). This study aimed to investigate the association of procedural factors during Nellix endograft deployment and patient outcomes. MethodsWe retrospectively reviewed 1-month imaging of 333 patients enrolled in the prospective, multicenter EVAS investigational device exemption trial between January 2014 and September 2016. Initial observations of those patients who met revised anatomic IFU yet still experienced late adverse events suggested that inadequate seal and low graft placement were common among these patients. Key procedural variables identified from a univariate analysis were applied to construct four cohorts stratified by procedural technical performance (technically adequate [P+] or technically inadequate [P−]) and the revised anatomic indications for use (anatomically within IFU [A+] or anatomically outside of IFU [A−]) and to compare them for aneurysm-related outcomes. A logistic regression analysis was performed to identify significant predictors of sac expansion or migration. ResultsProximal and distal seal zones and low graft placement were identified by logistic regression analysis as significant predictors of sac expansion or migration. Accordingly, acquisition of ≥10-mm proximal and distal seal zones and the position of the lowest stent within 10 mm of the lowest renal artery were clinically justified as thresholds for a technically adequate procedure. Patients who did not achieve these parameters were deemed to have a technically inadequate procedure. By use of the proposed procedural adequacy criteria and established anatomic criteria, patients were stratified into four cohorts: A+/P+ (n = 77), A+/P− (n = 54), A−/P+ (n = 71), and A−/P− (n = 131). Three-year estimates of freedom from migration of 10 mm were 98.6% in A+/P+, 95.9% in A+/P−, 85.8% in A−/P+, and 80.1% in A−/P−; freedom from type IA endoleak estimates were 98.6% in A+/P+, 100% in A+/P−, 96.4% in A−/ P+, and 90.3% in A−/P− cohorts. Freedom from sac expansion and secondary intervention were 96.9% and 90.6% in A+/P+, 86.0% and 93.6% in A+/P−, 87.1% and 83.1% in A−/P+, and 80.5% and 79.8% in A−/P− groups, respectively. Two early deaths (aneurysm-related mortality) on days 4 and 12 postoperatively were reported within the A+/P− group. Kaplan-Meier estimates of freedom from all-cause mortality and aneurysm-related mortality at 3 years were similar between cohorts. ConclusionsThis post hoc analysis suggests that achieving a 10-mm proximal and distal seal with adequate positioning of the endograft with respect to the renal arteries is associated with improved patient outcomes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.