Abstract

Micro-Tube Plasmas (μTP) have been gaining attention for applications ranging from medicine to material science and analytical chemistry due to their small size, low cost of operation and flexibility. In the present work a specific μTP, known as the Flexible Micro Tube Plasma (FμTP) is investigated experimentally and, for the first time, numerically as well. The creation, propagation mechanisms and properties of the ionization waves inside the microtube are investigated during the positive and negative half cycle of a μs square wave applied voltage. A two-dimensional (2D) axi-symmetric numerical model is developed and compared with optical emission spectroscopy showing good agreement. During the positive half cycle the plasma propagates as an ionization wave (or streamer) depositing charges on the dielectric wall. During the negative half cycle the plasma propagates due to the neutralization of those surface charges on the walls. The different propagation mechanisms affect the accumulation of charges, the induced electric field, and the speed of the ionization waves.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.