Abstract
Light trapping capability is the key phenomena of the photonic crystal fiber (PCF) which paves the broad range of applications. In this work, we control the light-guiding direction of the proposed PCFs via scaled-down approach to enhance the coupling between core-guided mode and surface plasmon polariton (SPP) mode resulting in the increase of sensitivity. We introduce the scaled-down air-holes in the first and second rings of the proposed PCF which provides the light guiding capability through the desire scaled-down region. A chemically stable plasmonic material gold is used outside the PCF structure to facilitate the detection of unknown analyte externally. Finite element method is used for numerical investigations, and the sensor performance is investigated by following the wavelength and amplitude interrogation methods. The proposed sensor shows the maximum wavelength sensitivities of 30000 and 22000 nm/RIU, and the maximum amplitude sensitivities of 1212 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> and 1506 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-1</sup> for x- and y-polarized modes, respectively in the analyte refractive index (RI) range of 1.33 to 1.39. It also shows high sensor wavelength resolution of 3.33 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-6</sup> RIU and 4.54 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">-6</sup> RIU, and a figure of merit about 508 and 500 for x- and y-polarized modes, respectively. It should be noted that the proposed PCF SPR sensor shows the significant sensing response for both polarization modes, as a result it will provide more freedom in choosing light source during practical implementation. Furthermore, the finding results indicates the proposed sensor will be effective for the detection of organic chemicals, biomolecules and medical diagnostics.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.