Abstract
In recent years, the fluorescence intensity ratio (FIR)-based technique for optical non-contact temperature measurement is of great interest to researchers due to its promising wide range of applications in high-voltage electricity fields, fires, corrosive environments, biological tissues, as well as other fields. Unfortunately, the FIR techniques based on thermally coupled energy levels (TCLs) often have the problem of low sensitivity as a result of the narrow energy gap. In contrast to FIR techniques with TCLs, the FIR technique with non-thermal coupled energy levels (NTCLs) is no longer restricted by the energy gap and is expected to achieve high signal resolution. In this study, we attempted to acquire a thermometric material that possesses high sensitivity as well as high signal resolution with the help of NTCLs. We successfully prepared NaYbF4:Er3+@NaYbF4:Tm3+ core-shell microcrystals by solvothermal technique using NaYbF4 as matrix and Er3+ and Tm3+ as luminescent centers and made necessary investigations on their crystal structures, microscopic morphologies, intrinsic mechanisms, and thermometric properties. The sample phosphors in a 980 nm laser show bright upconversion (UC) luminescence with emission peaks corresponding to the characteristic energy level jumps of Er3+ as well as Tm3+, respectively. The temperature sensing characteristic parameters have been investigated by FIR techniques with TCLs (2H11/2 → 4I15/2(Er3+)/4S3/2 → 4I15/2(Er3+)) & NTCLs (3H4→3H6(Tm3+)/1G4→3H6(Tm3+),3H4→3H6(Tm3+)/2H11/2 → 4I15/2(Er3+),3H4→3H6(Tm3+)/4S3/2 → 4I15/2(Er3+) and 3H4→3H6(Tm3+)/4F9/2 → 4I15/2(Er3+)), respectively. It is shown that the maximum absolute & relative sensitivities are 0.5677 K-1(495 K) as well as 1.20 % K−1(445 K) respectively with good thermal stability. In addition, the NTCLs have good separation of the emission bands, which enables the material to have excellent signal discrimination in temperature detection. These results indicate that the material is expected to be a potential candidate for optical thermometers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.