Abstract
Conducted electrical weapons are designed to cause temporary electro-muscular incapacitation (EMI) without significant injury. The objective of this study was to assess the risk and cause of spinal injury due to exposure to a benchtop EMI device. Porcine subjects were exposed to 19 and 40Hz electrical stimuli for a prolonged duration of 30sec. X-ray imaging, necropsy, and accelerometry found that lumbosacral spinal fractures occurred in at least 89% of all subjects, regardless of the stimulus group, and were likely caused by musculoskeletal fatigue-related stress in the lumbosacral spine. Spinal fractures occurred in the porcine model at an unusually high rate compared to human. This may be due to both the prolonged duration of electrical stimulation and significant musculoskeletal differences between humans and pigs, which suggests that the porcine model is not a good model of EMI-induced spinal fracture in humans.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.