Abstract

AbstractVirtual endoscopy is a promising medical application for volume‐rendering techniques where perspective projection is mandatory. Most of the acceleration techniques for direct volume rendering use parallel projection. This paper presents an algorithm to approximate perspective volume rendering using parallel projected slabs. The introduced error due to the approximation is investigated. An analytical study of the maximum and average error is made. This method is applied to VolumePro 500. Based on the error analysis, the basic algorithm is improved. This improvement increases the frame rate, keeping the global maximum error bounded. The usability of the algorithm is shown through the virtual endoscopic investigation of various types of medical data sets. Copyright © 2002 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.