Abstract
Coronary flow capacity (CFC) is a measure that integrates hyperemic myocardial blood flow and coronary flow reserve to quantify the pathophysiological impact of coronary artery disease on vasodilator capacity. This study explores the prognostic value of modified CFC derived from [15O]H2O positron emission tomography perfusion imaging. Quantitative rest/stress perfusion measurements were obtained from 1300 patients with known or suspected coronary artery disease. Patients were classified as having myocardial steal (n=38), severely reduced CFC (n=141), moderately reduced CFC (n=394), minimally reduced CFC (n=245), or normal flow (n=482) using previously defined thresholds. The end point was a composite of death and nonfatal myocardial infarction. During a median follow-up of 5.5 (interquartile range, 3.7-7.8) years, the end point occurred in 153 (12%) patients. Myocardial steal (hazard ratio [HR], 6.70 [95% CI, 3.21-13.99]; P<0.001), severely reduced CFC (HR, 2.35 [95% CI, 1.16-4.78]; P=0.018), and moderately reduced CFC (HR, 1.95 [95% CI, 1.11-3.41]; P=0.020) were associated with worse prognosis compared with normal flow, after adjusting for clinical characteristics. Similarly, in the overall population, increased resting myocardial blood flow (HR, 3.05 [95% CI, 1.68-5.54]; P<0.001), decreased hyperemic myocardial blood flow (HR, 0.68 [95% CI, 0.52-0.90]; P=0.007) and decreased coronary flow reserve (HR, 0.55 [95% CI, 0.42-0.71]; P<0.001) were independently associated with adverse outcome. In a model adjusted for the combined use of perfusion metrics, modified CFC demonstrated independent prognostic value (overall P=0.017). [15O]H2O positron emission tomography-derived resting myocardial blood flow, hyperemic myocardial blood flow, coronary flow reserve, and CFC are prognostic factors for death and nonfatal myocardial infarction in patients with known or suspected coronary artery disease. Importantly, after adjustment for clinical characteristics and the combined use of [15O]H2O positron emission tomography perfusion metrics, modified CFC remained independently associated with adverse outcome.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.