Abstract

Objective The present study investigated whether optic nerve sheath diameter (ONSD) could be used to predict neurological outcomes in post-cardiac arrest (CA) patients. Methods We performed a comprehensive literature search in the Cochrane Library, ScienceDirect, PubMed, and Web of Science from inception to June 2020 for eligible articles. Stata 14.0 software was used to calculate the pooled odds ratios (ORs) and 95% confidence intervals (95% CIs), sensitivity, specificity, summary receiver operating characteristic (SROC) curve, subgroup analysis, sensitivity analysis, and publication bias. Results Eight studies involving 473 patients were considered eligible for this meta-analysis. The pooled result using a random-effects model showed that broadened ONSD is associated with poor neurological outcomes in post-CA patients (OR = 15.62, 95% CI: 5.50–44.34, P < 0.001; I2 = 58.4%, P = 0.018), with a sensibility of 0.60 (95% CI: 0.45–0.73) and specificity of 0.94 (95% CI: 0.83–0.98). The area under the curve of the SROC curve for ONSD was 0.87 (95% CI: 0.84–0.90). Subgroup analysis revealed that sample size and time of ONSD measurement may be the source of heterogeneity. Sensitivity analysis demonstrated the stability of the results of this meta-analysis. No publication bias using Deeks' funnel plot was noted across the studies (P = 0.23). Conclusion This meta-analysis confirmed that ONSD can be used to predict neurological outcomes in post-CA patients.

Highlights

  • Cardiac arrest (CA) is a health problem worldwide and is associated with high rates of mortality and morbidity

  • Invasive methods are considered the gold standard in intracranial pressure (ICP) monitoring, they are associated with significant risks, such as bleeding and infection [3]

  • All the studies have to fulfill the following criteria: (1) clinical trials assessing the diagnostic accuracy of optic nerve sheath diameter (ONSD) for neurological outcomes in post-CA patients and (2) studies with complete information for the assessment of odds ratios (ORs) with 95% confidence intervals (CIs)

Read more

Summary

Objective

The present study investigated whether optic nerve sheath diameter (ONSD) could be used to predict neurological outcomes in post-cardiac arrest (CA) patients. Stata 14.0 software was used to calculate the pooled odds ratios (ORs) and 95% confidence intervals (95% CIs), sensitivity, specificity, summary receiver operating characteristic (SROC) curve, subgroup analysis, sensitivity analysis, and publication bias. Eight studies involving 473 patients were considered eligible for this meta-analysis. The pooled result using a random-effects model showed that broadened ONSD is associated with poor neurological outcomes in post-CA patients (OR = 15:62, 95% CI: 5.50–44.34, P < 0:001; I2 = 58:4%, P = 0:018), with a sensibility of 0.60 (95% CI: 0.45–0.73) and specificity of 0.94 (95% CI: 0.83–0.98). This metaanalysis confirmed that ONSD can be used to predict neurological outcomes in post-CA patients

Introduction
Methods
Results
Method of ONSD measurement
Discussion
Study design

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.