Abstract

A new technique has been developed for producing microspheres uniform in volume and fluorescence or radioactive tracer. Very uniform spheres with selected diameters are produced by introducing one liquid into the center of a moving stream of a second liquid (of differing surface tension) and breaking the core stream into uniform droplets by the action of a piezoelectric transducer. Fluorescent spheres of 10 μ diam have been produced having a coefficient of variation in volume and fluorescence as low as 3.6%. This corresponds to a diameter variation of about 1.5%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.