Abstract


 
 
 The Fast Fourier Transform (FFT) is the workhorse of condition monitoring analysis. The FFTs’ assumption of stationarity is often violated in rotating machinery. Even in a six second acquisition on a wind turbine, the shaft speed can change by 5%. For Shaft and Gear analysis, this is mitigated through the use of the time synchronous average. For general spectrum analysis, or bearing envelope analysis, there is no such mitigation: one hopes that the effect of variation in shaft speed is small. Presented is a time synchronous resampling algorithm which corrects for variation in shaft speed, preserving the assumption of stationarity. This allows for improved spectral analysis, such as used in bearing fault detection. This is demonstrated on a real world-bearing fault.
 
 

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.