Abstract

The results of the commercial indictor gas tube inv estigation, by the time delay measuring method are presented in this paper. This tube is usually used as a indicator of many electrical appliances. The experimentally obtained time delay distributions fo r different voltages (80 V, 90 V and 100 V) and different relaxation times (from 1 ms to 20 ms) are presented. It is shown that time delay distributio ns have Gaussian shape, and that used gas discharge tu be has very small memory effect. Small memory effect indicates fast response, and consequently go od characteristic for indicator tube.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.