Abstract

AbstractA corehole sampling project utilizing a wireline coring system provided sediment samples for microbiological characterization from deep unconsolidated sediments. Sampling tools were developed or modified to minimize contamination during sample acquisition and to facilitate stringent decontamination requirements. Quality assurance procedures, including the use of tracers, were implemented to minimize and quantify contamination from drilling hardware, drilling fluids and sample processing. Tracers included microspheres, potassium bromide, rhodamine dye, and perfluorocarbons, which enabled the detection and measurement of 1mg of drilling fluid per kg of sediment. In addition, sample processing was performed on‐site in an anaerobic chamber to prevent exposure of the subsurface materials to atmospheric oxygen concentrations. Sediment samples were then disbursed to investigators at National Laboratories and universities funded through the Department of Energy Subsurface Science Microbiology Program for microbiological characterization. Results of these efforts demonstrated that representative subsurface samples were collected and disbursed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.