Abstract
Ureteral injury is a well-known complication of radiofrequency ablation of renal tumors. Ureteral injury with cryoablation seems to be less common, but has been reported. Herein, the authors describe a technique that can be used to avoid direct ureteral injury during cryoablation of renal masses. Initial ice ball formation serves to fix the probe in the target. The mass and kidney can then be retracted away from the ureter to avoid direct involvement with the subsequent ice ball. The authors report three successful example cases, with no significant complications.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.