Abstract

The time spent in glucose ranges is a common metric in type 1 diabetes (T1D). As the time in one day is finite and limited, Compositional Data (CoDa) analysis is appropriate to deal with times spent in different glucose ranges in one day. This work proposes a CoDa approach applied to glucose profiles obtained from six T1D patients using continuous glucose monitor (CGM). Glucose profiles of 24-h and 6-h duration were categorized according to the relative interpretation of time spent in different glucose ranges, with the objective of presenting a probabilistic model of prediction of category of the next 6-h period based on the category of the previous 24-h period. A discriminant model for determining the category of the 24-h periods was obtained, achieving an average above 94% of correct classification. A probabilistic model of transition between the category of the past 24-h of glucose to the category of the future 6-h period was obtained. Results show that the approach based on CoDa is suitable for the categorization of glucose profiles giving rise to a new analysis tool. This tool could be very helpful for patients, to anticipate the occurrence of potential adverse events or undesirable variability and for physicians to assess patients’ outcomes and then tailor their therapies.

Highlights

  • Type 1 diabetes (T1D) is an autoimmune disease characterized by the destruction of pancreatic beta cells

  • We aim to present a methodology for the categorization of 24-h and 6-h periods of glucose data, based on a Compositional Data (CoDa) approach

  • We considered a linear discriminant (LD) model where the discrimination rule is based on compositional linear functions on x [34]

Read more

Summary

Introduction

Type 1 diabetes (T1D) is an autoimmune disease characterized by the destruction of pancreatic beta cells. Insulin infusion can be performed either with multiple daily injections (MDI) or with continuous subcutaneous insulin infusion (CSII). To avoid both high and low levels of BG (hyper- and hypoglycemia, respectively), insulin must be properly infused. Insulin dosing is usually adjusted by physicians according to patient’s characteristics, such as carbohydrate intake and body weight [2]. Even though current T1D technology allows the combination of continuous glucose monitoring (CGM) and CSII, achieving optimal glycemic control is very complicated due to large intra-patient variability [3]. Dealing with the complex behavioral characteristics of patients with T1D makes it difficult for physicians to adjust proper insulin dosing profiles to handle patient’s activities. The automatic adaptation of insulin therapy based on information from continuous glucose monitoring has been the subject of many developments in the field of DSSs and the artificial pancreas [6,7]

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call