Abstract
IntroductionThe efficacy and safety of photorefractive keratectomy (PRK) has been well documented, but outcomes of PRK enhancement following PRK remain understudied. This study aimed to evaluate the safety, efficacy, and predictability of PRK enhancement in patients with residual refractive error after primary PRK and compare these results to prior studies as well as Food and Drug Administration (FDA) safety and efficacy clinical endpoints.MethodsThis non-randomized, retrospective chart analysis included eyes with a history of PRK that underwent PRK enhancement at a single center. Post-enhancement data were documented at 3-month and 1-year visits. Patient characteristics between the study group and a control group who underwent primary PRK only were compared. Safety and efficacy measures included change in uncorrected distance visual acuity (UDVA), change in corrected distance visual acuity (CDVA), manifest refraction spherical equivalent (MRSE), amount of induced astigmatism, and presence of serious adverse events.ResultsA total of 188 eyes from 141 patients were included. When compared to the control group, women underwent PRK enhancement at a higher rate than men (P = 0.004). The group undergoing PRK enhancement had a higher sphere (P = 0.013) and spherical equivalent (P = 0.004) than the control group at the time of primary PRK. MRSE was reduced to − 0.97 ± 0.72 D (− 2.25 to + 2.13 D) from pre-enhancement values of − 0.98 ± 0.66 D (− 2.75 to + 1.75 D) and stable over 12-month visits with 86% and 98% of eyes within ± 0.50 D and ± 1.00 D of target, respectively. UDVA of 20/20 or better was achieved in 75% of eyes. The UDVA of 75% of eyes remained the same or improved by 1 or more Snellen lines compared with pre-enhancement CDVA.ConclusionOur results demonstrate that, when compared with previous studies, modern PRK enhancement after PRK has improved visual acuity and refractive outcomes. Though PRK enhancement is not an FDA approved procedure, we show that it meets or exceeds the FDA criteria for the correction of refractive error.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.