Abstract

In order to eliminate the fatigue failure of metallic thin film strain gauges under large alternating strain condition, a mechanical structure reducing the large strain on the target surface proportionally to a safe level is proposed as strain shunt in this study. The working principles of the strain shunt structure are illustrated and the shunt ratio of strain reduction is derived theoretically from a simplified one dimensional model. The prototype strain shunt is validated by tensile load test experiments which confirm the repeatability and linearity. Moreover, the usability of the strain shunt structure under alternating loads, the stability of shunt ratio under the combined stress conditions, and the dynamic response of the strain shunt structure are investigated by finite element analysis.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call