BackgroundIMRT provides higher dose conformation to the target and dose sparing to surrounding tissues than 3DCRT. Monte Carlo method in Medical Physics is not a novelty to approach dosimetric problems. A new PENELOPE based code named PRIMO recently was published. The most intriguing features of PRIMO are the user-friendly approach, the stand-alone property and the built-in definition of different linear accelerators models. Nevertheless, IMRT simulations are not yet implemented.MethodsA Varian Trilogy with a Millennium120 MLC and a Varian Novalis with 120HD MLC were studied. A RW3 multi-slab phantom was irradiated with Gafchromic films inserted between slabs. An Expression 10000XL scanner (Seiko Epson Corp., Nagano, Japan) was used to digitalize the films. PTW-Verisoft software using the global Gamma Function (2%, 2 mm) was used to compare simulated and experimental results.The primary beam parameters were adjusted to best match reference data previously obtained in a water phantom. Static MLC simulations were performed to validate the MLC models in use. Two Dynamic IMRT preliminary tests were performed with leaves moving with constant and variable speed. A further test of an in phantom delivery of a real IMRT field allowed simulating a clinical-like MLC modulation.ResultsSimulated PDD, X- and Y-profiles in reference conditions showed respectively 100.0%, 100.0% and 99.4% of Gamma points < 1 (2%, 2 mm). Static MLC simulations showed 100.0% of Gamma points < 1 with the 120HD MLC and 99.1% with the Millennium compared with the scanned images.The fixed speed test showed 99.5 and 98.9% of Gamma points < 1 respectively with two different MLC configuration-sampling algorithms when the 120HD MLC was used. The higher modulation MLC motion simulation showed 99.1% of Gamma points < 1 with respect to the experimental. This result depends on the number of the fields to reproduce the MLC motion, as well as calculation time. The clinical-like simulation showed 96.2% of Gamma points < 1 using the same analysis conditions.ConclusionsThe numerical model of the Varian Trilogy and Novalis in the PRIMO software was validated. The algorithms to simulate MLC motion were considered reliable. A clinical-like procedure was successfully simulated.
Highlights
Intensity-Modulated Radiation Therapy (IMRT) provides higher dose conformation to the target and dose sparing to surrounding tissues than 3D conformal RT (3DCRT)
In this paper we present the results of a preliminary feasibility study of PRIMO Monte Carlo (MC) simulations of IMRT procedures on Varian RT units
This study focuses on the simulation of two specific RT units, both equipped with Varian 2300IX linear accelerators (LINAC) head: a Varian Trilogy using Millennium120 as Multi Leaf Collimators (MLC) and a Varian Novalis mounting 120HD MLC
Summary
IMRT provides higher dose conformation to the target and dose sparing to surrounding tissues than 3DCRT. Intensity-Modulated Radiation Therapy (IMRT) [1,2,3,4] is an External Radiotherapy advanced technique, nowadays considered as one of the standard Radiotherapy (RT) treatment modalities. It is generally able to provide a higher dose conformation to the target and significantly higher dose sparing to surrounding tissues than conventional treatment methods such as 3D conformal RT (3DCRT). This superior treatment modality needs a dedicated quality assurance (QA) program to ensure the safety of patients and to minimize the uncertainties associated with the procedure. A comprehensive QA in advanced RT should require patient-specific dose verifications
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have