Abstract

Background: Reconstruction techniques for anterior glenoid bone loss have seen a trend from screws to suture-based fixations. However, comparative biomechanical data, including primary fixation and glenoid-graft contact pressure mapping, are limited. Hypothesis: Suture-based bone block cerclage (BBC) and suspensory suture button (SB) techniques provide similar primary fixation and cyclic stability to double-screw fixation but with higher contact loading at the bony interface. Study Design: Controlled laboratory study. Methods: In total, 60 cadaveric scapulae were prepared to simulate anterior glenoid bone loss with coracoid autograft reconstruction. Graft fixation was performed with 3 different techniques: (1) an interconnected all-suture BBC, (2) 2 SB suspensions, and (3) 2 screws. Initial compression was analyzed during primary fixation. Cyclic peak loading with 50 N and 100 N over 250 cycles at 1 Hz was performed with a constant valley load of 25 N. Optical recording and pressure foils allowed for spatial bone block tracking and contact pressure mapping at the glenoid-graft interface. Load-to-failure testing was performed at a rate of 1.5 mm/s with ultimate load and stiffness measured. Results: Initial graft compression was higher with screw fixation (141 ± 5 N) compared with suture-based fixations (P < .001), with BBC fixation providing significantly higher compression than SB fixation (116 ± 7 N vs. 91 ± 5 N; P < .001). Spatial bone block migration and ultimate failure load were similar between the BBC and screw groups. The SB group showed significantly increased bone block translation (3.1 ± 1.0 mm; P≤ .014) and rotation (2.5°± 1.4°; P≤ .025) and significantly lower ultimate failure load (180 ± 53 N) compared with the BBC (P = .046) and screw (P = .002) groups. Both suture-based fixations provided significantly increased graft-glenoid contact loading with higher pressure amplitudes (P≤ .032) and contact pressure after cyclic loading (+13%; SB: P = .007; BBC: P = .004) compared with screw fixation. Conclusion: Both SB and interconnected cerclage fixation improved dynamic contact loading compared with screw fixation in a biomechanical glenoid bone loss model. Cerclage fixation was biomechanically comparable with screw fixation but with a greater variability. SB fixation showed significantly lower primary fixation strength and greater bone block rotation and migration. Clinical Relevance: Suture-based bone block fixations improved graft-glenoid contact loading, but the overall clinical consequence on healing remains unclear.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call