Abstract

Preoperative virtual planning and the use of patient-specific implants enable exact reconstruction of orbital fractures. We present our results and experience of reconstruction of isolated orbital fractures with patient-specific implants, according to the Helsinki protocol, in 15 patients who were followed up for at least three months postoperatively. The mean (range) difference between the positions of virtually planned, and postoperative, implants was 1.9 (0.5–5.6) mm. The postoperative volume of the fractured orbit was 1.34ml less than that of the non-fractured side, but this was not clinically relevant. None of the patients required reoperation and none had any implant-related complications during follow up. We conclude that patient-specific implants are an adaptable and reliable treatment for primary orbital trauma, and that the Helsinki protocol may have wider applications in the treatment of facial fractures.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.