Abstract

To compare the primary and secondary stability of conventional (≥ 8-mm) and extrashort (4-mm) implants in edentulous patients using different methods of assessment. Patients underwent implant surgery and were randomly allocated into two groups: test, with two conventional implants in the anterior region and two extrashort (4-mm) implants in the posterior region; and control, with two conventional (≥ 8-mm) implants in the anterior region only. Primary stability (S1-implant placement) was assessed by insertion torque, implant stability quotient (ISQ, Osstell), and damping capacity (PTV, Periotest), while secondary stability (S221-21 days after S1; and S2clip-at prosthetic loading, ± 3 months after S1) was evaluated by ISQ and PTV. The statistical significance level was set at P < .05. Fifty conventional implants and 24 extrashort implants were placed in 25 patients. The overall survival rate was 97.3%. There was no statistically significant difference between the insertion torque of conventional and extrashort implants (P > .05). PTV values were significantly lower for conventional implants only at S2clip (P = .041). ISQ values were significantly greater for conventional implants at S1 (P = .004), whereas at S221 and S2clip, no differences were found (P = .413 and P = .490, respectively). Damping capacity showed no significant differences between S1-S2M21 and S1-S2clip. ISQ values showed a significant increase of stability between S1-S2clip, for conventional (P = .022) and extrashort (P = .005) implants, which was different from that observed between S1-S221. There was a moderate negative correlation between the PTV and ISQ variables (r = 0.5) of extrashort implants, and between the PTV and insertion torque (r = -0.3) of conventional implants. For extrashort implants, there was a null correlation between ISQ and torque (r = 0.0). There was a moderately positive correlation between ISQ and torque (r = 0.3) in the conventional implant group. The results suggest that extrashort and conventional implants present similar primary and secondary stability values and may similarly influence restorative protocols.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.