Abstract

This research was conducted in the raw material testing laboratory of PT. ABC is a textile company. This study aims to minimize downtime on the thermo-circulation dryer. This tool serves to dry samples of raw materials or fabrics that are tested in the PT. ABC. The method used is preventive maintenance with block replacement. The results of the calculation of the Thermo Circulation Dryer Inspection Schedule obtained comparative results, namely, In the initial condition the inspection frequency is 1 time per year with a downtime value of 0.391 days. Meanwhile, the result of the proposal is that 1.29 times a year inspection is carried out with an expectation of 0.303 days of downtime or 2.11 hours less. The results of the proposed preventive maintenance schedule for the Circulating Thermo Dryer are 1.29 times per 365 days or the equivalent of 2 times for one year.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.