Abstract
The ion flux is measured spatially resolved along the substrate surface in dual-frequency large area capacitive discharges operated in H2 at 150 Pa. One electrode is driven by 40.68 MHz and/or 81.36 MHz. The dependence of the ion flux profile on the applied voltage waveform is investigated experimentally and by a two-dimensional model. The results show that lateral inhomogeneities caused by standing wave effects can be eliminated based on the electrical asymmetry effect, i.e., by tuning the phase shift between the two applied frequencies. This approach solves one of the major problems in plasma processing of large substrates.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.