Abstract

Cooling pipe system (CPS) in concrete arrays plays an important role to control the temperature changes in massive concrete such as dams, foundation bridges, etc. The application of CPS in massive concrete has also been studied by some researchers but only in positive qualities point of view of the CPS. The present study presents the results of an investigation of thermal behavior regarding crack formation due to the hydration heat in massive concrete structures. To reduce the thermal load and improve the reliability of protection against cracks in massive concrete, the temperature changes, particularly the temperature field and thermal stress, in such concrete with the presence of CPS were simulated and calculated with the help of the advanced computer programs. In addition, both the temperature field and the cracking index in the massive concrete with the CPS’s temperature of 15 °C were determined. As the results, the cracking index over time was greater than the allowable value of 1.5, which indicates that the risk of cracking did not occur when the CPS was applied in the massive concrete.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.