Abstract

To demonstrate a simple, practical, cheap method of preventing potentially fatal aspiration of a dislodged voice prosthesis; this method was developed by a laryngectomised patient. A patient diagnosed with squamous cell carcinoma of the larynx underwent total laryngectomy. Upon completion of radiotherapy, a tracheoesophageal fistula was created and a voice prosthesis inserted to enable voice restoration. Unfortunately, the patient presented subsequently with repeated episodes of dislodgement and an episode of potentially fatal aspiration of the voice prosthesis, despite various measures taken by the surgeons to overcome the problem. The patient subsequently developed a method enabling him to retrieve the voice prosthesis himself should it become dislodged. He attached a ring to the prosthesis, which was larger in diameter than the tracheal stoma, thus preventing ingestion or recurrence of aspiration. To our knowledge, this is the first report in the world literature of this form of innovation, created by a laryngectomised patient, to overcome the problem of aspiration or ingestion of a dislodged voice prosthesis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.