Abstract

The purpose was to study the efficiency of the use of aspiration equipment of the BC type and its efficiency of use today in comparison with the advanced achievements of aspiration technology in the elevator industry for the process of creating air dilution and removing grain dust during the operation of equipment using the example of a modern silo elevator with a capacity of 20,000 tons, in grain production, including acceptance and storage of air-conditioned grains. In order to achieve the purpose of the study and answer the research questions about the effectiveness of the installations of battery cyclones of the BC type, a calculation was made on the amount of grain dust emitted for a period of 365 days of elevator operation in 3 shifts according to the "Temporary method of calculating planned indicators for the protection of atmospheric air of grain processing enterprises and elevators", in accordance with the "Calculation Method aspiration installations and explosion-discharge devices", series 14, issue 1 "Industrial safety of explosive grain storage and processing facilities".

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.