Abstract

The production of prosthetic valve incompetence during atriotomy closure is among the operative maneuvers utilized to prevent air embolism in mitral valve replacement. The leaflets of a porcine bioprosthesis may be retracted safely and effectively, thereby producing temporary valve incompetence, by placing three polypropylene sutures through the valve orifice and around the sewing ring to encircle the leaflets. These traction sutures are easily pulled out through the atriotomy suture line after all air has been displaced from the heart. The technique has been effective, easily accomplished, and without complications.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.