Abstract

BackgroundRecently, intracardiac echocardiography emerged as a useful tool in the electrophysiology laboratories for guiding transseptal left heart catheterizations, for avoiding thromboembolic and mechanical complications and assessing the ablation lesions characteristics. Although the value of ICE is well known, it is not a universal tool for achieving uncomplicated access to the left atrium. We present a case in which ICE led to interruption of a transseptal procedure because several risk factors for mechanical complications were revealed.Case presentationA case of a patient with paroxysmal atrial fibrillation and atrial flutter, and distorted intracardiac anatomy is presented. Intracardiac echocardiography showed a small oval fossa abouting to an enlarged aorta anteriorly. A very small distance from the interatrial septum to the left atrial free wall was seen. The latter two conditions were predisposing to a complicated transseptal puncture. According to fluoroscopy the transseptal needle had a correct position, but the intracardiac echo image showed that it was actually pointing towards the aortic root and most importantly, that it was virtually impossible to stabilize it in the fossa itself. Based on intracardiac echo findings a decision was made to limit the procedure only to ablation of the cavotricuspid isthmus and not to proceed further so as to avoid complications.ConclusionThis case report illustrates the usefulness of the intracardiac echocardiography in preventing serious or even fatal complications in transseptal procedures when the cardiac anatomy is unusual or distorted. It also helps to understand the possible mechanisms of mechanical complications in cases where fluoroscopic images are apparently normal.

Highlights

  • Intracardiac echocardiography emerged as a useful tool in the electrophysiology laboratories for guiding transseptal left heart catheterizations, for avoiding thromboembolic and mechanical complications and assessing the ablation lesions characteristics

  • The possibility to visualize the oval fossa, the LA free wall and the aortic root helps in preventing mechanical complications

  • The value of ICE is well known, it is rather hard to admit that it is a universal tool for achieving uncomplicated access to the left atrium

Read more

Summary

Conclusion

We strongly believe that this case is a good illustration of the usefulness of the ICE in the electrophysiology field and further enhances its value as a tool for avoiding complications when the intracardiac anatomy is unusual or distorted. LA – left atrium; left atrial http://www.cardiovascularultrasound.com/content/3/1/5. The oval shape in the center of the screen is the non-coronary sinus of Valsalva. Is the right atrium at the bottom of which the transseptal needle is clearly visible. The membrane of the oval fossa, adjacent to the right-hand part of the non-coronary aortic sinus shows bidirectional flapping motion. Intracardiac echocardiography showing sliding of the needle towards the aorta. The transseptal needle is already in the oval fossa with its tip pointing to the aorta. This is especially clearly visible after a premature beat. 8. Ren J-F, Marchlinski FE, Callans DJ: Left atrial thrombus associated with ablation for atrial fibrillation: identification with intracardiac echocardiography.

Background
Discussion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.