The New York Bridge and Tunnel Commission began planning for a tunnel beneath the lower Hudson river to connect Manhattan to New Jersey in 1919. At 8,300 feet, it would be the longest tunnel for passenger vehicles in the world. A team of engineers and physiologists at the Yale University Bureau of Mines Experiment Station was tasked with calculating the ventilation requirements that would provide safety from exposure to automobile exhaust carbon monoxide (CO) while balancing the cost of providing ventilation. As the level of ambient CO which was comfortably tolerated was not precisely defined, they performed human exposures breathing from 100 to 1,000 ppm CO, first on themselves and subsequently on Yale medical students. Their findings continue to provide a basis for carbon monoxide alarm requirements a century later.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.