Abstract
Magnetic resonance imaging (MRI)-negative epilepsy may be successfully solved with a multidisciplinary approach using invasive recordings, image and signal analysis. The whole methodology used by the epilepsy surgery team is systematically described based on an resistant epilepsy case with all steps and rationale of choosing different investigation methods from surface electroencephalography (EEG) to invasive recordings. Due to negative MRI and non-concordant ictal surface EEG with clinical semiology, the patient was investigated with stereo- EEG (SEEG), aiming to delimitate epileptogenic and eloquent cerebral areas. Implantation strategy, seizures recordings, stimulation, resection planning using quantitative EEG analysis, and the surgery plan are presented. The patient has been seizure-free for 14 months so far, with improved behavior and daily life quality. Post-operative examination revealed focal cortical dysplasia type II B.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.