Abstract
Bronchodilator therapy for COPD may be delivered by a number of different inhaler devices. To determine the efficacy of pressurised metered dose inhalers (pMDI) compared to any other handheld inhaler device for the delivery of bronchodilators in non-acute COPD. The Cochrane Collaboration, Asthma and Wheeze Randomised Controlled Clinical Trials register was searched for studies. The UK pharmaceutical companies who manufacture inhaled COPD medication were also contacted. Two reviewers independently reviewed the results of computerised search and any potentially relevant articles were obtained in full. One reviewer extracted details of each trial and a second reviewer checked all extracted data. Dichotomous outcomes such as exacerbation rate were assessed using relative risk, with 95% confidence interval (CI). Fourteen studies appeared potentially relevant but only three studies (61 patients) met the entry criteria. Two studies compared a dry powder device (Turbuhaler or Rotahaler) with a pMDI for beta2-agonist delivery, and one (36 patients cross-over design) the Respimat (soft mist device for ipratropium) vs a pMDI. For the Turbuhaler and Rotahaler, none of the reported outcome measures were significantly different. The Rotahaler study used a high and low dose of medication with or without large volume spacer. The study using the Respimat showed significant increases in FEV1 when compared to a pMDI (difference in change from base line 70 ml, 95% CI 10, 130 ml). The effect on change in FVC was of similar size. There were no differences between these two devices for any other reported outcomes. Although none of the included studies required prior patient ability to use any of the inhalers (and no study mentioned device training), it was assumed that all patients randomised into the study would have undergone training in use of the study inhalers and were capable of using those devices. In patients with stable COPD, pMDI produced similar outcomes to a dry powder device for delivering beta2-agonists, but the very small number of studies and included patients does not permit firm conclusions to be drawn. The soft mist device for ipratropium was more effective than a pMDI, but the data come from one small study. There need to be further well designed randomised controlled trials to define the role of inhaler devices using bronchodilators in stable COPD.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.