Abstract

Airway closure, functional residual capacity (FRC) and transpulmonary pressure-volume curves were assessed for each lung separately in the anaesthetized subject by means of a double lumen tracheal catheter. In the supine position airway closure occurred synchronously in the two lungs and 0.2-0.31 above FRC. The pressure- volume curves in both lungs were rather similar and critical closing pressure (CP) was approximately 3 cmH2O in each lung. In the left lateral posture, FRC was increased in the non-dependent and reduced in the dependent lung, while closing capacity (CC) remained unaltered. Airway closure was asynchronous and discontinuous between the two lungs. This was caused by the non-linear transpulmonary pressure-volume curve in the lungs, in conjunction with the vertical pleural pressure gradient. An interpulmonary "pendelluft" phenomenon was observed in the left lateral posture, increasing inhomogeneity of ventilation. It may depend on regional differences in compliance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.