Abstract

Fifteen neonates and infants were investigated during pressure controlled ventilation (PCV) and pressure support ventilation (PSV) on a Servo 300 ventilator. Changes in cardiac output (aortic mean blood flow velocity) were assessed with the Doppler technique. During PSV cardiac output increased by 16% (P < 0.01) compared with PCV with equal ventilation. Mean airway pressure decreased significantly during PSV compared with PCV, which may explain the increased cardiac output. During PSV, when inspiratory/expiratory (I:E) relations are dependent on the patient, we found a lower I:E ratio compared with PCV. It can be assumed that at least part of the decreased mean airway pressure is caused by the lower I:E ratio. As the heart rate was unchanged, the variations in cardiac output were caused by alterations in stroke volume. It is concluded that a patient triggered mode should be preferred providing that the neonate/infant has the ability to elicit the ventilator's triggering system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.