Abstract

In this paper, the pressure pulsation of Wanjiazhai Francis turbine at six monitoring points under different loads is monitored. Fast Fourier Transform(FFT) was used to perform time-frequency conversion, and the data was analyzed from both time-domain and frequency-domain perspectives. From a time perspective, the pressure pulsation at the upstream bladeless area is the most sensitive to changes in power. From a frequency perspective, the frequency components of pressure pulsation are more complex when P=40kW, while the frequency domain diagrams of pressure pulsation at each monitoring point are similar when P=80kW and P=120kW.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.