Abstract
Pressure distributions in a diamond anvil cell with a rhenium gasket have been measured at various pressures up to 212±6 GPa using energy dispersive x-ray diffraction with a synchrotron source. Three sets of type IA yellow diamonds were used with bevels of 5°, 7°, and 10°. For the 7°-beveled tips, a 5-μm-diam collimated beam was used to a pressure of 206±6 GPa. In the other experiments, collimators of 10–30 μm were used. In the region of the 50-μm central flat, the pressure was essentially uniform. The effect of finite collimator size on the measurement of pressure profiles is also analyzed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.