Regarding the Japan Sodium-cooled Fast Reactor, a multi-elbow piping system is adopted for its cold-legs. Flow Induced Vibration (FIV) is considered to be caused by complex flow with very high velocity in the elbows. In this study, pressure measurement test of a single elbow flow is conducted to find out pressure fluctuation characteristic which is related to the elbow turbulent flow and lead potentially to the FIV. Two types of experimental loops, that is, 1/7 and 1/15-scale setup simulating the JSFR cold-leg pipings, are used for pressure measurement, and a distinguishing peak can be seen in the power spectrum density profile of pressure fluctuation obtained where flow separation occurs and at the downstream from it. This characteristics of pressure fluctuation is obtained from the two different scale experiments, and the scale effect is not found in terms of the pressure fluctuation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.