Abstract

This paper is focused on the residual capacity of steel columns, as a damage criterion. Load-Impulse (P-I) diagrams are frequently used for analysis, design, or assessment of blast resistant structures. The residual load carrying capacity of a simply supported steel column was derived as a damage criterion based on a SDOF computational approach. Dimensionless P-I diagrams were generated numerically with this quantitative damage criterion. These numerical P-I diagrams were used to show that traditional constant ductility ratios adopted as damage criteria are not appropriate for either the design or damage assessment of blast resistant steel columns, and that the current approach could be a much more appropriate alternative.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.