Abstract

The pumped-storage hydropower station is the most reliable, economic, long-term, large capacity, and mature energy storage technology in the power system, and it is an important component of renewable energy. Cavitation and water column separation of a pumped storage unit are important and widely researched factors in the safe and stable operation of a unit. This study focused on the evolution of water column separation of a pump turbine and its relationship with the pressure distribution of the cross section of a draft tube as well as the pressure pulsation characteristics of different measuring points in the cross section of the draft tube. A pumped storage experimental platform that can realize water column separation is established, and experiments with different opening angles are carried out. The results show that there are three factors that impact water column separation and cavitation: gas nucleus, vaporization pressure, and duration of vaporization pressure. Water column separation is the development and continuation of cavitation. The difference between the center pressure of the vortex rope and the wall pressure is large, reaching 2.23 m at a large opening. The pressure fluctuation amplitude of the wall measuring point is greater than that of the other measuring points in the same cross section, but the frequency characteristics are the same. In the transition process, the pressure pulsation amplitude of the liquid column bridging is the largest, and the largest pressure pulsation amplitude can reach 4.18 m at a small opening.