Abstract

A general analytical method has been devised for determining the pressure drop due to flow development in the entrance region of ducts of arbitrary cross section. The essential feature of the analysis is that the pressure drop can be determined without actually solving for the entrance-region velocity development. Instead, the calculation only requires a knowledge of the fully developed velocity profile. Application of the method is made to a variety of cross sections including the circular tube, elliptical ducts, rectangular ducts, isosceles triangular ducts, and annular ducts. Numerical results are presented and comparisons are made with available experiments and with prior analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.